飛宇光點提供各種AWG產(chǎn)品,包括50GHz,100GHz和200GHz的無熱AWG(高斯AWG)和有熱AWG(平頂AWG),這里給大家展示41通道無熱高斯AWG
Athermal AWG(AAWG) have equivalent performance to standard Thermal AWG(TAWG) but require no electrical power for stabilization. They can be used as direct replacements for Thin Film Filters(Filter type DWDM module) for es where no power is ailable, also suitable for outdoor applications over -30 to +70 degree in access networks. Flyin’s Athermal AWG(AAWG) provide excellent optical performance, high reliability, ease of fiber handling and power sing solution in a compact package. Different input and output fibers, such as SM fibers, MM fibers and PM fiber can be selected to meet different applications. We can also offer different product packages, inluding special metal box and 19” 1U rackmount.
The planar DWDM components(Thermal/Athermal AWG) from Flyin Optronics are fully qualified according to Telcordia reliability assurance requirements for fiber optic and opto-electronic components (GR-1221-CORE/UNC, Generic Reliability Assurance Requirements for Fiber Optic Branching Components, and Telcordia TR-NWT-000468, Reliability Assurance Practices for Opto-electronic Devices).
Optical Specification (Gaussian Athermal AWG)
| Parameters | Condition | Specs | Units | ||
| Min | Typ | Max | |||
| Number of Channels |
| 41 |
| ||
| Number Channel Spacing | 100GHz | 100 | GHz | ||
| Cha. Center Welength | ITU frequency. | C -band | nm | ||
| Clear Channel Passband |
| ±12.5 | GHz | ||
| Welength Stability | Maximum range of the welength error of all channels and temperatures in erage polarization. | ±0.05 | nm | ||
| -1 dB Channel Bandwidth | Clear channel bandwidth defined by passband shape. For each channel | 0.24 |
|
| nm |
| -3 dB Channel Bandwidth | Clear channel bandwidth defined by passband shape. For each channel | 0.43 |
|
| nm |
| Optical Insertion Loss at ITU grid | Defined as the minimum transmission at ITU welength for all channels. For each channel, at all temperatures and polarizations. |
| 4.5 | 6.0 | dB |
| Adjacent Channel Isolation | Insertion loss difference from the mean transmission at the ITU grid welength to the highest power, all polarizations, within the ITU band of the adjacent channels. | 25 |
|
| dB |
| Non-Adjacent, Channel Isolation | Insertion loss difference from the mean transmission at the ITU grid welength to the highest power, all polarizations, within the ITU band of the nonadjacent channels. | 29 |
|
| dB |
| Total Channel Isolation | Total cumulative insertion loss difference from the mean transmission at the ITU grid welength to the highest power, all polarizations, within the ITU band of all other channels, including adjacent channels. | 22 |
|
| dB |
| Insertion Loss Uniformity | Maximum range of the insertion loss variation within ITU across all channels, polarizations and temperatures. |
|
| 1.5 | dB |
| Directivity(Mux Only) | Ratio of reflected power out of any channel(other than channel n)to power in from the input channel n | 40 |
|
| dB |
| Insertion Loss Ripple | Any maxima and any minima of optical loss across ITU band, excluding boundary points, for each channel at each port |
|
| 1.2 | dB |
| Optical Return loss | Input & output ports | 40 |
|
| dB |
| PDL/Polarization Dependent Loss in Clear Channel Band | Worst-e value measured in ITU band |
| 0.3 | 0.5 | dB |
| Polarization Mode Dispersion |
|
|
| 0.5 | ps |
| Maximum Optical Power |
|
|
| 23 | dBm |
| MUX/DEMUX input/ output Monitoring range |
| -35 |
| +23 | dBm |
IL Represents the worst e over a +/-0.01nm window around the ITU welength;
PDL was measured on erage polarization over a +/- 0.01nm window around the ITU welength.